AESCULAP Minimally Invasive Surgery
Unit for production of monopolar and/or bipolar frequency for use with various instruments on patients.
5
Products
Sorting
Loading...
Loading...
- Product search type Electrosurgical Unit
- Aesculap Product Groups Neurosurgery
- Product family Neuroendoscopy
- Monopolar / Bipolar bipolar
- Dimenions 305 x 305 x 82 mm
- Weight 4.70 kg
- Power supply 100-120 V AC, 50/60Hz 220-240 V AC, 50/60Hz
- Maximum power consumption 140.0 W
- Surgical Step Others
- Type of Sterilization not to be sterilized
- Product contains Latex No
- Sterility non-sterile
- Disposable / Reusable reusable
Source
- Product search type Electrosurgical Unit
- Aesculap Product Groups Neurosurgery
- Product family Equipment
- Monopolar / Bipolar bipolar
- Surgical Step Others
- Type of Sterilization not to be sterilized
- Data Matrix No
- Product contains Latex No
- Sterility non-sterile
- Disposable / Reusable reusable
Source
- Product search type Electrosurgical Unit
- Brand name LEKTRAFUSE
- Aesculap Product Groups Endoscopic Technology
- Product family Equipment
- Monopolar / Bipolar bipolar
- Weight 8.10 kg
- Bipolar Output Watt Ohm BICUT 1 100 600 BICOAG 100 100 BICUT 2 100 100
- Frequency 447.0 kHz
- Modulation frequency bipolar 460 kHz
- EMV EN 60601-1-2
- Power supply 100-240 V AC
- Maximum power consumption 470.0 VA
- Indication Laparoscopy Thoracoscopy
- Discipline General Surgery
- Type of Sterilization not to be sterilized
- Protection level acc EN_606011 CF
- Safety class acc to EN 60601-1 I
- Tested acc to norm EN 60601-1 EN 60601-2-2
- Product contains Latex No
- Sterility non-sterile
- Disposable / Reusable reusable
Source
GN300
- Product search type Electrosurgical Unit
- Aesculap Product Groups Endoscopic Technology
- Product family Equipment
- Monopolar / Bipolar monopolar bipolar
- Weight 9.30 kg
- Monopolar Output Watt Ohm SPRAY COAG 80 700 -1200 POWERCUT 1 300 250 - 600 POWERCUT 2 200 250 - 600 POWERCUT 3 150 250 - 600 CONTACT COAG 120 250 - 600 POWERCUT 4 100 250 - 600
- Bipolar Output Watt Ohm BICOAG 80 70 - 250 BICUT 80 700 -1300
- Frequency 447.0 kHz
- Modulation frequency monopolar 20 kHz
- Modulation frequency bipolar 1 kHz
- EMV EN 60601-1-2
- Maximum power consumption 550.0 VA
- To be used with (code) GN330 GN324 GN310 GN090 GN088 GN325
- Indication Thoracoscopy Hysteroscopy Laparoscopy
- Discipline Ear-Nose-Throat Surgery Arthroscopy
- Type of Sterilization not sterilized ex works
- Protection level acc EN_606011 CF
- Safety class acc to EN 60601-1 I
- Tested acc to norm EN 60601-1 EN 60601-2-2
- Product contains Latex No
- Sterility non-sterile
- Disposable / Reusable reusable
- Width (mm) 305.000 mm
- Height 155.000 mm
- Depth (mm) 305.000 mm
Source
GN640
Nelson Deluxe Electrosurgical generator, monopolar/bipolar; without mains cord and accessories, to be used with GN090; GN324; GN325; GN330; GN088 and suitable monopolar and bipolar cables
- Product search type Electrosurgical Unit
- Brand name NELSON DELUXE
- Aesculap Product Groups Endoscopic Technology
- Product family Equipment
- Monopolar / Bipolar bipolar monopolar
- Weight 8.60 kg
- Monopolar Output Watt Ohm POWERCUT 4 150 500 POWERCUT 3 200 500 POWERCUT 2 250 500 SPRAY COAG 120 800 FORCED COAG 120 1000 SEALCUT 100 150 SOFT COAG 100 300 POWERCUT 1 300 500 MICROCUT 1 + 2 300 500 CONTACT COAG 120 500
- Bipolar Output Watt Ohm BICUT 2 100 100 BICOAG 100 100 BICUT 1 100 600
- Frequency 447.0 kHz
- Modulation frequency monopolar 20 kHz
- Modulation frequency bipolar 1 kHz
- EMV EN 60601-1-2
- Maximum power consumption 470.0 VA
- To be used with (code) GN090 GN088 GN324 GN325 GN330
- Indication Laparoscopy Hysteroscopy Thoracoscopy
- Discipline Ear-Nose-Throat Surgery Arthroscopy
- Type of Sterilization not sterilized ex works
- Protection level acc EN_606011 CF
- Safety class acc to EN 60601-1 I
- Tested acc to norm EN 60601-2-2 EN 60601-1
- Product contains Latex No
- Sterility non-sterile
- Disposable / Reusable reusable
- Width (mm) 305.000 mm
- Height 175.000 mm
- Depth (mm) 305.000 mm
Source