AESCULAP Minimally Invasive Surgery
The Herloon System consists of a reusable Trocar Body including a blunt trocar pin as well as a single-use balloon shaft with a distal balloon and a single-use hand-pump.
Indication:
- Hernia surgery
- Retroperitoneal access in endoscopic urology
Features:
- Balloon System for extraperitoneal hernia surgery
- System is based on a silicon flap valve
- Dissection of peritoneum and abdominal wall is done by a balloon
- Dilated transparent balloon allows clear view of body structures.
- Elastic balloon material, allowing dilatation and adaption to body structures.
- Adaption of the balloon shaft to the reusable trocar body by engaging and securing with a retention ring
- Cost-effective system
4
Products
Sorting
Loading...
Loading...
- Product Search Type Balloon Shaft
- Aesculap Product Groups Endoscopic Technology
- Product family Access/Trocars
- Diameter (mm) 10.00 mm
- to be used with (code) EJ871R
- Minimally Invasive Surg. (MIS) Yes
- Surgical Step Minimal-invasive access
- Indication TEP Hernia Repair Thoracoscopy Laparoscopy
- Type of Sterilization Gamma
- Sales Unit package of 10 pieces
- Disposable / Reusable disposable
- Sterility sterile
- Product contains Latex No
Source
- Product Search Type Trocar Body with Obturator
- Aesculap Product Groups Endoscopic Technology
- Product family Access/Trocars
- Diameter (mm) 10.00 mm
- Colour green
- Minimally Invasive Surg. (MIS) Yes
- Surgical Step Minimal-invasive access
- Indication Thoracoscopy Laparoscopy
- Type of Sterilization not sterilized ex works
- UDI Direct Marking No
- Disposable / Reusable reusable
- Sterility non-sterile
- Product contains Latex No
Source
- Product Search Type Trocar Body
- Aesculap Product Groups Endoscopic Technology
- Product family Access/Trocars
- Diameter (mm) 10.00 mm
- Colour green
- to be used with (code) EJ873R
- Minimally Invasive Surg. (MIS) Yes
- Surgical Step Minimal-invasive access
- Indication Hernia Repair TEP Laparoscopy Thoracoscopy
- Type of Sterilization not sterilized ex works
- UDI Direct Marking Yes
- Disposable / Reusable reusable
- Sterility non-sterile
- Product contains Latex No
Source
- Product Search Type Obturator
- Author HASSON
- Aesculap Product Groups Endoscopic Technology
- Product family Access/Trocars
- Working length (mm) 300.0 mm
- Working length (Inch) 11 3/4"
- Diameter (mm) 10.00 mm
- Tip profile blunt working tip
- to be used with (code) EJ872R
- Minimally Invasive Surg. (MIS) Yes
- Surgical Step Minimal-invasive access
- Indication Laparoscopy Thoracoscopy
- Type of Sterilization not sterilized ex works
- UDI Direct Marking Yes
- Disposable / Reusable reusable
- Sterility non-sterile
- Product contains Latex No
Source